Lon Smith Ventilation

Print E-mail

Attic Ventilation

Ventilation is crucial to the life and effectiveness of every roofing system. Vapors and condensation can cripple R-values and encourage hidden decay in the building structure. Lon Smith’s A1 Certified personnel will create a system that performs where you see it, and where you can’t.

Lon Smith Ventilation

It is estimated that 9 out of 10 homes in North America do not have proper attic ventilation. Why? Because most people are unaware that attic ventilation can impact the longevity of their entire home!

For example, in the summer, an improperly ventilated attic can cause heat to build in excess of 160°F. This superheated air eventually penetrates the ceiling insulation into the living area below.

Types of damage that can result include:

  • Premature aging of your roofing system (“fried” shingles)  
  • Warping, cracking, or breaking down of wood framing 
  • Damage to siding, exterior or interior paint, and wallpaper 
  • Higher energy costs

A properly ventilated attic can help reduce the load on your air conditioner by moving the superheated air out of your attic before it builds up and causes damage. In the winter, various household appliances, bathtubs, showers, and cooking vapors can contribute to excess moisture build-up. Improperly ventilated attics will allow this moisture to collect and cling to the underside of the roof. There, it will condense and fall, soaking the attic insulation and reducing its efficiency

Additional structural damage can include:

  • Roof deck warping and rotting of the wood frame 
  • Mildew growth 
  • Buckling of shingles and felt

OC Roofing System WholeProper Attic Ventilation

Proper attic ventilation systems allow a continuous flow of outside air through the attic (see illustration at right), protecting the efficiency of the insulation and helping to lower temperatures in the living space.

It consists of a balance between air intake (at your eaves or soffits) and air exhaust (at or near your roof ridge).

The FHA (Federal Housing Administration) recommends a minimum of at least 1 square foot of attic ventilation (both intake and exhaust) for every 300 square feet of attic space. For example, if your attic is 900 square feet, you need a total of 3 square feet of ventilation. This amount is generally divided equally between intake and exhaust ventilation (i.e., 11/2 feet of each), to insure proper air flow through the attic.

Please Contact Me

Lon Smith Honored Again

One Of America’s Top Roofing Companies Lon Smith Roofing ranked as One of the Top 15 in America!

Read The Whole Story

Lon Smith Roofing

Dallas, Fort Worth, Austin Texas
Toll Free: (800) 317-4791

Contact Form

Join Lon Smith On Our Facebook Page


Connect With Us On Facebook!

Video Testimonials

Lon Smith Roofing Video Testimonials No one says it better than our satisfied and grateful customers. Continue by clicking the View Videos button below to enter our Testimonials Video Vault.

View Videos

Owens Corning Media Center

Owens Corning Video Education Center Enter our Owens Corning Media Center to learn more about Energy Savings, Cultured Stones, Insulation, Shingles, and more. .

Media Center

Lon Smith Blog

The Lon Smith Roofing & Construction Blog Stay up to date about new products, specials, weather concerns, and more. Visit our Lon Smith Roofing & Construction Blog.

Lon Smith Blog